HIMA B5233 B 5233-1/-2 H51q-HS/HRS System Assembly Kit
HIMA B5233 B 5233-1/-2 H51q-HS/HRS System Assembly Kit
Product Type: Assembly Kit
Payment:T/T, Western Union
Shipping Port:Jinhua China
Lead Time:1-3 Working Days
Condition: Brand New And 100% Original
Warranty: 12 months
Parts of the assembly kit B 5233-1/-2:
• 1 x K 1412A central rack, 5 units high, 19 inch, with integrated
cable tray, with a hinged receptable for the label.
• additional modules on the rear
3 x Z 6011 decoupling and fusing to feed the power supply
modules
1 x Z 6012 fan module with fan run monitoring and fuse
monitoring
2 x Z 6013 decoupling and fusing of the supply voltage for the
WD signal
includes the modules:
• 3 x F 7126 power supply module 24 V / 5 V, each 10 A (PS1 - PS3).
The 5 V outputs of the power supply outputs are switched in parallel.
• 1 x F 7131 power supply monitoring
• 2 x F 8650 central module (CU1, CU2)
• 2 x F 7546 bus termination module (B 5233-1)
• 4 x F 7546 bus termination module (B 5233-2)
• 1 x BV 7032 data connecting cable (only B 5233-1)
modules for option (separate order)
• 6 x F 8621A Coprocessor module (CM11 - CM13, CM21 - CM23)
• 10 x F 8625 Ethernet-communication module
• 10 x F 8626 Profibus-DP-communication module
Assembly kits to be used for the I/O level:
• B 9302 I/O-rack 4 units high, 19 inch
• B 9361 additional power supply, 5 V DC, 5 units high, 19 inch
The max. current must be 18 A, if 3 x F 7126 are used to keep the system
in operation even one power supply module F 7126 has failed. The total
required current of the control is the summary of the consumption of the
modules in the central rack and of the I/O modules. For the values of the
current requirement (+5 V DC) refer to the data sheets.
View full details
• 1 x K 1412A central rack, 5 units high, 19 inch, with integrated
cable tray, with a hinged receptable for the label.
• additional modules on the rear
3 x Z 6011 decoupling and fusing to feed the power supply
modules
1 x Z 6012 fan module with fan run monitoring and fuse
monitoring
2 x Z 6013 decoupling and fusing of the supply voltage for the
WD signal
includes the modules:
• 3 x F 7126 power supply module 24 V / 5 V, each 10 A (PS1 - PS3).
The 5 V outputs of the power supply outputs are switched in parallel.
• 1 x F 7131 power supply monitoring
• 2 x F 8650 central module (CU1, CU2)
• 2 x F 7546 bus termination module (B 5233-1)
• 4 x F 7546 bus termination module (B 5233-2)
• 1 x BV 7032 data connecting cable (only B 5233-1)
modules for option (separate order)
• 6 x F 8621A Coprocessor module (CM11 - CM13, CM21 - CM23)
• 10 x F 8625 Ethernet-communication module
• 10 x F 8626 Profibus-DP-communication module
Assembly kits to be used for the I/O level:
• B 9302 I/O-rack 4 units high, 19 inch
• B 9361 additional power supply, 5 V DC, 5 units high, 19 inch
The max. current must be 18 A, if 3 x F 7126 are used to keep the system
in operation even one power supply module F 7126 has failed. The total
required current of the control is the summary of the consumption of the
modules in the central rack and of the I/O modules. For the values of the
current requirement (+5 V DC) refer to the data sheets.